Fire Suppression Pressure Relief Venting

Protect the integrity of your suppression enclosure during discharge. MEP Fire supplies and installs pressure relief venting systems that manage the pressure created by gaseous fire suppression.

Release The Pressure Without Affecting Fire Suppression

The pressure that builds from a gaseous suppression system can strain the enclosure and environment it’s designed to protect. If that pressure isn’t relieved, it can exceed what the building structure is designed to withstand. This can cause serious damage and create a safety risk for people in or around the affected area.

You need a way for the pressure to escape, but also ensure the extinguishing agent is kept in the room to effectively suppress the fire. Getting this balance right is essential to make sure the suppression system, protected room and pressure relief arrangement work together as intended.

For contractors, that means pressure relief can be incorporated into the wider system design instead of a problem to solve further down the line. For asset owners and facilities teams, it doesn’t just mean less risk of damage, but also less risk to the safety of everyone in the building.

MEP Fire supplies pressure relief venting with every gaseous suppression system, considering the requirements of the protected enclosure and the system as a whole.

Pressure Relief Calculated Around Your Suppression System

Gas suppression pressure relief vents can’t just allow as much pressure to escape as possible. The vent needs to respond to the pressure created during discharge while enabling the suppression system to maintain the required extinguishing-agent concentration. Too little pressure relief can place unnecessary loads on the protected enclosure. Too much or poorly planned venting can require extra building work, more penetrations into the protected enclosure, and higher installation costs 

Correct sizing depends on the agent, the discharge rate, the room volume and the strength of the enclosure, and is calculated as part of your system design. Inert gas and chemical gas systems generate high peak pressures and almost always need venting. We calculate the required vent area for each installation during the system design phase.

Depending on the building layout and system requirements, pressure can be relieved through cascade venting, released into a suitable adjacent space or ducted directly to the atmosphere. Our in-house engineering team can carry out the calculations and design reviews to determine the right arrangement for each installation. Pressure relief venting can also be integrated into a post-discharge extract system as a combined solution to prevent multiple penetrations into the protected area and simplify duct work.

Why Choose MEP Fire For Your Pressure Relief Venting?

Specialist suppression knowledge
MEP Fire understands how pressure relief interacts with gaseous suppression, room integrity and the wider protected environment, helping ensure your pressure relief vent supports the entire system.

In-house engineering expertise
Our in-house engineering team supports system design, installation and commissioning, keeping technical knowledge connected to delivery throughout the project.

Integrated delivery
Pressure relief can be delivered alongside your gaseous suppression system, reducing interfaces between different specialist contractors and keeping responsibility within one fire protection package.

UK-wide operations

Our specialist engineering resources are positioned across the UK, supported by operational bases in Slough and Liverpool, allowing us to support projects and maintenance requirements nationwide.

Ready to Protect Your Facility?

Get in touch with our team of fire suppression experts to discuss your requirements and receive a tailored solution.

Frequently Asked Questions

When a gaseous suppression system discharges, it releases a large volume of gas into a sealed room very quickly, and that creates a sudden change in pressure. Without somewhere for that pressure to go, the force can damage walls, windows, ceilings and doors, or even compromise the very seal the system depends on. A pressure relief vent is an automatic damper fitted to a room protected by gas suppression that opens during a discharge to release excess pressure and protect the building structure.

A pressure relief vent is a damper set into the wall of the protected room that stays closed in normal use and opens automatically when the pressure from a discharge reaches a set point. This lets the peak pressure bleed off while the room still retains enough agent to suppress the fire. The vent then closes again. The aim is to protect the building fabric without letting so much gas escape that the system can no longer hold its design concentration. 

Discharging a large volume of gas quickly into a sealed room causes a rapid pressure change that can damage walls, windows and doors unless it is relieved.

Yes, all systems need pressure relief venting. The vent size is confirmed by calculation during system design.

A fire suppression pressure relief vent is installed in the enclosure wall of the protected room, positioned so pressure can escape to a safe area without letting the agent leak away too quickly.