Data Fire Suppression & Protection

Just suppressing a fire with a traditional system isn’t enough when you’ve got valuable equipment to protect and operational continuity to preserve. These facilities need the earliest possible warning and suppression that doesn’t itself cause damage. MEP Fire works across the data sector, protecting mission-critical environments where uptime is everything. 

The Fire Protection Challenges in Data Centres

When working in the data sector, your chosen fire suppression system has to do more than stop a fire. It needs early detection, to be the right type of solution to avoid damage to highly sensitive equipment, and work within an environment where any downtime can cost a business a significant amount of time and money, plus impact its reputation. 

For data centre operators and project teams, the challenge is finding protection that works alongside the facility instead of adding to the risks. Putting out the fire is one part, but if operations are down and detailed cleanup is needed, the system isn’t right for the requirements of your environment. 

Densely packed equipment generates heat and high airflow, which can carry away the early signs of a fire before conventional detection reacts. Operational factors like this mean that a specialist data centre fire suppression system is needed for projects in this sector. 

We arrange the necessary security access, plan works to protect uptime and respect redundancy arrangements, and coordinate closely with data centre operators and their engineering teams. Understanding how these facilities are run, and what continuity means to the business, we deliver and maintain protection without putting the operation at risk.

Fire Suppression Designed Around Your Data Project

We focus on the specific risks in data fire protection, assessing the requirements of each project before recommending the most appropriate solution. Our in-house engineers work across multiple fire suppression and detection technologies. This allows us to design your fire protection around your specific needs, considering the facility as a whole and developing protection that works alongside the wider infrastructure. 

Assessing risk before selecting the solution

Our engineers work across several suppression technologies and manufacturers, so they can design and install systems based on the risks and requirements of the environment. For data centres, this can include inert gas suppression, chemical gas suppression, watermist, or aerosol depending on the equipment and the space available.

Early warning for critical environments

Data environments need to be able to detect a developing fire as quickly as possible to reduce the risk of damage to sensitive equipment. For these applications where high airflow is a factor, carefully designed aspirating smoke detection systems can continuously sample the air for early signs of smoke. Sampling points and pipework arrangement should be planned around the airflow within the protected environment.

Designed around the protected space

Fire protection needs to work with the enclosure, the equipment, and the operational requirements of the facility. MEP Fire can design the wider system around requirements including cylinder storage, pipework, and pressure relief venting, helping ensure the protection is considered as a complete engineered system.

Protecting Your Critical Data Infrastructure

  • Data halls and server rooms – we consider fire risk and the sensitivity of the equipment when designing a solution for server room fire suppression and essential network infrastructure.
  • UPS systems – battery installations and UPS systems add to risks in data environments. We assess the specific application and build systems around the equipment and room configuration.
  • Switch rooms – the electrical infrastructure in switch rooms needs to be protected without impacting wider facility operations. Our engineers can coordinate fire protection with surrounding electrical and M&E services. 
  • Back-up generator enclosures – generator equipment presents fire risks that need to be considered in line with the operational requirements. We assess the application and design fire protection around the enclosure and infrastructure. 

Ready to Protect Your Facility?

Get in touch with our team of fire suppression experts to discuss your requirements and receive a tailored solution.

Frequently Asked Questions

High airflow from cooling can dilute and carry away the early signs of a fire, so very early, sensitive detection is usually needed.

Yes, data centre protection can extend across a range of critical spaces, including server and data rooms, UPS and battery rooms, switch rooms, BMS rooms, transformer rooms and plant areas. The appropriate detection and fire suppression system for data centres can differ between environments, so each area should be assessed according to its specific risk.

Gaseous suppression can be appropriate for critical environments containing sensitive electrical and IT equipment where introducing water into the protected space can lead to more damage and residue left behind. MEP Fire provides both inert gas and chemical gas suppression, with the choice depending on the requirements of the individual environment.

Yes, we plan work carefully to protect continuity, respect redundancy arrangements and coordinate closely with your engineering team.

Yes, we take account of redundancy and concurrent maintainability and work within the operational controls these facilities depend on.